Log on to the page Chemical testing (SAIF) Click Here. New users please register and get your user id and password.
-
Click on sample submission form.
-
Choose the instrument/analysis technique from the drop down menu.
Fill up the form below with sample code, sample description ( sample matrix , solvent etc), and Specific requirements.
Click on submit.
Follow the same procedure if you need multiple analysis.
Get printouts of each form obtain signature from supervisor /HoD/Principal of the institute.
Send the samples along with these forms and payment details to the address given below.
Samples should be submitted separately for each analysis technique ( thin films coated over glass substrate s are exempted from this rule).
Samples will not be returned after analysis. if you need samples back please collect it directly with in a week of date of dispatch of results.
Submit samples in air tight vials, Without damage during transit.
Re submission of samples will be accepted along with FORM 7 only available at forms and downloads .
Payment details
- Payment Details
-
The analysis charge is given at Click here . The charges are inclusive of taxes. To arrive at total analysis cost multiply the analysis charge in the table by number of samples for that particular analysis. add Rs 100/- towards email/postal charge to the total analysis charge. payments for all analysis at a time can be done together.
-
Address for submitting the sample: The Director, STIC, Cochin University P.O,Kochi 682022, Kerala, India,
-
Samples can be submitted by India Post/Speed Post/courier
Sample Quantity Required and Other Details
Thermo Gravimetric Analysis-DTA | Differential Scanning Calorimetry (DSC) |
Quantity required 20mg | Quantity required 20mg |
Powder/liquid | Powder/liquid |
Explosives (Nitrate containing samples) and Oil samples will not be accepted | Explosives (Nitrate containing samples) and Oil samples will not be accepted |
CHNS Analysis | ICP-MS |
Quantity: 20 mg or 15 ml | Quantity: 200 mg of solid sample or 50 ml digested solution. |
Powder/liquid Mention if halogen is present | Details of sample matrix is mandatory. Standards of 50 elements are available. Mention all required elements. |
FTIR spectrometer analysis |
UV vis NIR Spectrophotometer |
Quantity required 10 mg |
100 mg if solid (DRS method) 20 ml if liquid |
Powder/liquid |
powder / liquid /thin films |
Thin films / bulk material / gass |
NMR Analysis |
MALDI- TOF |
10 mg / 6ml Pure sample solid/liquid |
100 micro liter/0.1mg (liquid/solid) |
Check the solubility in following Solvents available Chloroform, DMSO, Acetone, Methanol, Water |
Specify the mass range and MATRIX |
For higher option and please contact laboratory |
Submit matrix which are not available with us. please contact laboratory |
Powder XRD |
Single crystal XRD |
75mg solid samples, dimension 1.5 cm x 1.5 cm x 0.5cm ( polymer /metal) |
4-5 crystals, Good quality crystal 2mm at least. Preserve in mother liquid or in liquid paraffin |
Powder, thin films solid samples polymers etc |
Submit following details along with crystal: possible atoms present, details of all solvents used. Expected structure If known |
SEM-EDAX |
HR-TEM |
10mg |
10mg |
Powder/Solid samples Metal or other solid specimen Dimension 1 cm x 1cm x 0.5 cm (lbh) |
Powder /liquid dispersion, hard polymers.
Sample Suitability for Electron Microscopy (Applicable for instruments without cryo facility or dual lens system, available at SAIF cochin) 1. Samples must be stable under an accelerating voltage of 200 keV. Any disintegration during analysis may compromise the vacuum system and prevent image capture. 2. Samples must be non-magnetic. Magnetic properties will be verified in the laboratory. 3. Samples must be completely dry and free of moisture. Please note: The analysis fee is non-refundable if the sample fails to meet any of the above conditions. Para magnetic samples may be accepted. |